Specification

Model DG4V-3 DG4V-3S DG4V-3R
Pressure Limits
P, A and B ports
350 bar (5075 psi) 350 bar (5075 psi) 350 bar (5075 psi)
T port 210 bar (3045 psi) 100 bar (1450 psi) 210 bar (3045 psi)
Flow rating See performance data See performance data See performance data
Relative duty factor Continuous; ED = 100% Continuous; ED = 100% Continuous; ED = 100%
Type of protection:
ISO 4400 coils with plug
fitted correctly
IEC 144 class IP65 IEC 144 class IP65 IEC 144 class IP65
Coil winding Class H Class H Class H
Lead wires (coils type F***) Class H Class H Class H
Coil encapsulation Class F Class F Class F
Maximum Permissable voltage fluctuation:
Refer to temperature limits Refer to temperature limits Refer to temperature limits
Minimum 90% rated 90% rated 90% rated
Typical response times at 100% rated volts measured from application/removal of voltage to full spool displacement of “2C” spool at:
Flow rate P-A, B-T 40 l/min (10.6 USgpm) 20 l/min (5.3 USgpm) 20 l/min (5.3 USgpm)
Pressure 175 bar (2537 psi) 175 bar (2537 psi) 175 bar (2537 psi)
AC (~) energizing 15 ms 18 ms 18 ms
AC (~) de–energizing 23 ms 32 ms 32 ms
DC (=) energizing 45 ms 60 ms 60 ms
DC (=) de–energizing 28 ms 40 ms 40 ms
Power consumption, AC
solenoids (for coils listed in model code)
Initial                          Holding
VA (RMS)                 VA (RMS)
Initial                         Holding
VA (RMS)                VA (RMS)
Initial                         Holding
VA (RMS)                VA (RMS)
Full power coils:
Dual frequency coils at 50 Hz 280                                     61 280                                     61 N/A
Dual frequency coils at 60Hz 300                                     58 300                                     58 N/A
Low power coils,
“BL” and “DL”:
(Not available with “N” –
No-spring detented models)
Low power coils
not usable with
DG4V-3S valves.
170                                     37 N/A
Dual frequency coils at 50 Hz -                                          - 190                                     37 N/A
Dual frequency coils at 60Hz -                                          - -                                          - N/A
Power consumption, DC solenoids at rated voltage and 20 C (68 F)
Full power coils:
12V, model type “G” 30W                                    - 30W                                    - N/A
24V, model type “H” 30W                                    - 30W                                    - N/A
Low power coils:
12V, model type “GL” Low power coils
not usable with
DG4V-3S valves.
-                                         18W N/A
24V, model type “HL” 18W                                    - N/A
24V, HM Coil 8W                                      - N/A

 